1 / 4
| Appearance Structure | Dimensions (L x D x H) | 700mm x 400mm x 1700mm |
| Weight | 122kg | |
| Length of Charging Cable | 5m | |
| Electrical Indicator | Connectors | CCS2 || GBT * Single |
| Output Voltage | 200 - 1000VDC | |
| Output Current | 0 to 1200A | |
| Insulation (Input - Output) | >2.5kV | |
| Efficiency | ≥94% at nominal output power | |
| Power Factor | >0.98 | |
| Communication Protocol | OCPP 1.6J | |
| Functional Design | Display | Customize according to requirements |
| RFID System | ISO/IEC 14443A/B | |
| Access Control | RFID: ISO/IEC 14443A/B || Credit Card Reader (Optional) | |
| Communication | Ethernet – Standard || 3G/4G Modem (Optional) | |
| Power Electronics Cooling | Liquid Cooled | |
| Work Environment | Operating Temperature | -30 °C to 55°C |
| Working || Storage Humidity | ≤ 95% RH || ≤ 99% RH (Non-condensing) | |
| Altitude | < 2000m | |
| Ingress Protection | IP54 || IK10 | |
| Safety Design | Safety Standard | GB/T 18487 2023, GB/T 20234 2023, GB/T 27930 |
| Safety Protection | Overvoltage protection, lightning protection, overcurrent protection, leakage protection, waterproof protection, etc. | |
| Emergency Stop | Emergency Stop Button Disables Output Power |