China Hot Sale New Design 60kw 120kw CCS2 Gbt Chademo DC Electric Vehicle Charging Station EV Charging Pile Manufacturer, Supplier

60KW 120KW DC charging pile is also fast charging pile, DC charging station can provide enough power, the output voltage and current adjustment range is large, can realize the requirement of fast charging. Its charging speed is much faster than AC charging pile, using three-phase four-wire 380V voltage, charging time is 1-3 hours, while AC slow charging will take 7-10 hours. DC charging pile generally take double gun design, double waterproof, dustproof, compatible with new and old national standard car, over voltage, under voltage, overload, short circuit, leakage, over temperature, low temperature, lightning and other protection.

Product Description

Product Description

DC Charging Pile is a kind of efficient charging equipment designed for electric vehicles. Its core advantage is that it can directly provide DC power to the battery pack of electric vehicles, eliminating the intermediate link of on-board chargers converting AC power to DC power, thus achieving faster charging speed. With its high power output, this technology is able to replenish a large amount of power to the electric vehicle in a short period of time, greatly enhancing the user's charging efficiency and driving experience.

The DC charger integrates advanced power electronics technology inside, which can precisely control the output of current and voltage to meet the charging needs of different brands and models of electric vehicles. It is also equipped with multiple safety protection mechanisms, including over-current protection, over-voltage protection, short-circuit protection, and leakage protection, to ensure safety during the charging process. With the continuous expansion of the electric vehicle market and the advancement of technology, the application range of DC charging piles is also gradually expanding. It is not only widely used in public car parks, highway service areas and other major traffic routes, but also gradually penetrated into residential communities, commercial centres and other daily life scenarios.

Advantage Display
📋

Product Parameters

Technical Specifications
Equipment Models BHDC-180KW/240KW
AC Input Voltage range (V) 380±15%
Frequency range (Hz) 45~66
Input power factor ≥0.99
Fluoro wave (THDI) ≤5%
DC Output Workpiece ratio ≥96%
Output Voltage Range (V) 200~750
Output power (KW) 60 120
Maximum Output Current (A) 120 240
Charging interface 2
Charging gun length (m) 5m
Display & Control Machine display 7 inch color touch screen
Charging operation swipe or scan
Communication Ethernet (Standard Protocol)
Heat dissipation Air cooling
Size(W*D*H)mm 700*565*1630
Installation method Floor type
Environment Operating temperature(℃) -20~50
Altitude (m) ≤2000
Relative humidity 5%-95%

Product Feature

AC Input DC chargers first input AC power from the grid into a transformer, which adjusts the voltage to suit the needs of the charger's internal circuitry.
DC Output The AC power is rectified and converted to DC power via charging modules. Several modules can be connected in parallel to meet high power requirements.
Control Unit The technical core responsible for controlling switching, output voltage, and current to ensure safety and efficiency.
Metering & Interface Records power consumption for billing and utilizes a standard-compliant interface for EV connection and safety.
Details Display
🚀

Application Scenarios

DC charging piles are widely used in public charging stations, highway service areas, commercial centers and other places, providing fast charging services for electric vehicles.

Public Transport: Essential for city buses, taxis, and operating vehicles requiring quick turnaround.
Commercial Areas: Ideal for shopping malls, supermarkets, hotels, and logistics parks.
Residential Areas: Meeting the growing demand as electric vehicles enter private households.
Highway Stations: Installed in service areas or petrol stations for long-distance EV travelers.
Application 1
Application 2
🖼

Product Showcase

Production
Station
?

Frequently Asked Questions

What is the main advantage of using a DC charging pile?
The main advantage is speed. DC chargers bypass the vehicle's on-board charger and provide power directly to the battery, significantly reducing charging time compared to AC chargers.
What is the power efficiency of these chargers?
Our DC chargers feature a high efficiency rate of ≥96%, ensuring minimal energy loss during the power conversion process.
Are there safety protections included in the equipment?
Yes, the units are equipped with multiple safety mechanisms, including over-current, over-voltage, short-circuit, and leakage protection to ensure a safe charging environment.
Can the charging gun length be customized?
The standard charging gun length is 5 meters. However, we offer optional lengths of 8 meters or 10 meters to suit different site requirements.
What kind of maintenance does the DC charger require?
The charger uses an air-cooling system for heat dissipation. Periodic checks of the filters and ensuring the cooling vents are clear of obstructions are generally all that is required.
Is the charger suitable for outdoor use?
Yes, it is designed for various environments with an operating temperature range of -20°C to 50°C and can handle relative humidity between 5% and 95%.